Cable de aislamiento de XLPE con cinta semiconductora de conductor de cobre,Cable de alimentación N2XSY NA2XSY NA2XSEY N2XSRY NA2XSRY N2XSEBY N2XSEY,Cable de cubierta de aluminio corrugado
Tipo de Pago: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Cantidad de pedido mínima: | 500 Meter |
Plazo de entrega: | 30 días |
Modelo: N2XSY NA2XSY NA2XSEY N2XSRY NA2XSRY N2XSEBY N2XSEY
Solicitud: Central eléctrica, Industrial, Subterráneo, Construcción
voltaje: Cable de alta tensión
Corriente: Cable de CA
Material de aislamiento: XLPE
Material de la envoltura: Reticulación
Forma del material: Alambre redondo
Material del núcleo del alambre: Cable de cobre desnudo
Proceso de dar un título: VDE, UL, RoHS, CE, CCC, ISO
Brand: HUAYUAN YONGTONG
Paquete: TAMBORES
productividad: 100KM/M
Marca: HUAYUAN YONGTONG
transporte: Ocean,Land,Air
Lugar de origen: BEIJING, CHINA
Capacidad de suministro: 100KM/M
Certificados : CE ISO CCC
HS-Code: 8544601900
Hafen: Tianjin Port,Shanghai Port,Qingdao Port
NO. | ITEM | UNIT | DATA |
1.0 | Name of Manufacturer: | Beijing Huayuan GaokeCable Co.,Ltd. | |
1.2 | Country of Manufacturer: | China | |
2.0 | Which type of manufacturing process viz. Continuous Catanery Vulcanisation (CCV) or vertical Catanery Vulcanisation system (VCV) or horizontal MDCV will be used to ensure circularity and concentricity of the extruded layers around the conductor. | VCV | |
3.0 | Type of Cable: | Cu/XLPE/Al/PE | |
4.0 | Rated nominal voltage | kV | 130/225 |
5.0 | Rated Maximum voltage | kV | 245 |
6.0 | Nominal cross-sectional area of Conductor | Sq.mm | 800 |
7.0 | Conductor | ||
7.1 | Material | copper | |
7.2 | Shape & formation | segment & in 5 segment for into circular | |
7.3 | Diameter of conductor | mm | 34.4 |
7.4 | Dia.Of Single Wire/Number of strands | mm | 2.56/185 |
8.0 | Conductor Screen | ||
8.1 | Material | Semi-conductor nylon tape +Super slippery Semi conductive XLPE Material | |
8.2 | Thickness of semi conducting tape | mm | 0.14 |
8.3 | Thickness of seim-conductot XLPE | mm | 2 |
8.4 | Diameter of Sime-conductor(Approx.) | mm | 38.4 |
9.0 | Insulation | ||
9.1 | Material | super purity material/XLPE | |
9.2 | Insulation Thickness(Min.Avg.) | mm | 23 |
9.3 | Diameter of Insulation(Approx.) | mm | 84.1 |
10.0 | Insulation Screen | ||
10.1 | Material | Super slippery Semi conductive Material | |
10.2 | Insulation Screen Thickness(Approx.) | mm | 1.2 |
10.3 | Diameter of Sime-Insulation(Approx.) | mm | 86.5 |
11.0 | Swellable type water blocking semi –conducting tape | ||
11.1 | Material | semi conductive water swellable tape | |
11.2 | Approximate thickness | mm | 2.0 |
11.3 | Diameter of Swellable tape (Approx.) | mm | 93.5 |
12.0 | Metallic Sheath: | ||
12.1 | Material | Corrugated Aluminum | |
12.2 | Constructional feature. | Corrugated | |
12.3 | Thickness of the sheath (Radial) | mm | 2.4 |
12.4 | Diameter of the cable across the metallic sheath(Approx.) | mm | 110.3 |
13.0 | Anti-corrosion layer | ||
13.1 | Material | asphaltum | |
13.2 | Thickness of the anti-corrsion | 0.2 | |
13.3 | Diameter of the cable Anti-corrosion(Approx.) | 110.7 | |
14.0 | Outer Shealth | ||
14.1 | Material | MDPE | |
14.2 | Outer Sheath Thickness(Nominal) | 4.5 | |
14.3 | Over Diameter(Approx.) | 119.7 | |
15.0 | Conductor Weight | kg/km | 7156 |
16.0 | Total Cable Weight (Approx.) | kg/km | 16530 |
17.0 | Minimum Bending Radius | ||
17.1 | During Installation | mm | 2300 |
17.2 | Installed | mm | 1800 |
18.0 | Maximum Pulling Tension | ||
18.1 | Of Conductor | kN | 56 |
18.2 | Of Metallic Sheath: | kN | 56 |
19.0 | Continuous current rating under the specified installation and operating conditions. Conductor temperature 90° | ||
C .Air temperature +40°C . Ground temperature +35° C and depth of laying 1500 mm | |||
19.1 | In Air | Amp | 1032 |
19.2 | In Ground | Amp | 801 |
19.3 | In pipeline | Amp | 762 |
20.0 | Maximum value of electric stresses at the conductor screen | kV/mm | 8.62 |
21.0 | Maximum value of dielectric stress at the insulation | kV/mm | 3.9 |
22.0 | Short circuit capacity of conductor for 1/2/3 second assuming conductor temperature of 90 °C prior to short circuit and 250 °C during short circuit | ||
22.1 | 1.0 Secs | kA | 160.8 |
22.2 | 2.0 Secs | kA | 114.8 |
22.3 | 3.0 Secs | kA | 66.8 |
23.0 | Short circuit capacity of metallic sheath for 1/2/3 second at screen temperature of 75 °C prior to short circuit and 200 °C during short circuit | ||
23.1 | 1.0 Secs | kA | 31 |
24.0 | Ionization factor at 50 Hz. (Tan Delta) | 0.0005 | |
25.0 | Sheath voltage under maximum operating conditions assuming all circuits connected | kV per km | 0.112 |
26.0 | TTST | ||
Maximum D.C. resistance of conductor per km. at 20 | |||
26.1 | degree C. | Ohm | 0.0221 |
26.2 | Maximum A.C. resistance of conductor per km. at 90 degree C. | Ohm | 0.0311 |
26.3 | Maximum electrostatic capacitance per km. of cable. | μF | 0.162 |
26.4 | Partial discharge at 2 Uo 1.50 Uo | pc | ≤ 5 |
26.5 | A.C. Enduring Test voltage 2.0U0/ hours | kV/mim | 318/30 |
26.6 | D.C.Out sheath Enduring Test voltage | kV/mim | 25kV/1min |
26.7 | Impulse test voltage | kV | 1050 |
27.0 | Approximate drum dimension (dia & width) | mm/mm | 3500*2400 |
28.0 | Maximum length of cable in a drum (Metres) | m | 550 |
29.0 | Minimum length of cable in a drum (Metres) | m | 500 |
30.0 | Approximate gross weight of cable in a drum (MT) | 9.3 | |
31.0 | Expected Cable life. | Year | 30 |
CU / X LPE 130/225 ( 2 45 ) k V 1 × 800 mm 2
Construction |
Thickness(mm) |
Diameter(mm) |
1--Conductor |
|
34.4(+0.6,-0.5) |
2--Semi-conducting tape |
0.14 |
35.7 |
3--Conductor screen |
1.2 |
38.1 |
4--XLPE insulation |
23.0 |
84.1 |
5--Insulation screen |
1.2 |
86.5(+1.5,-1.5) |
6--Semi-conducting bedding tape |
2.0 |
93.5 |
8--Corrugated Al sheath |
2.4 |
110.3 |
9-MDPE outer sheath (including graphite) |
4.5 |
119.7(+3.0,-2.5) |
Tambor
d1: 3500 mm
L1: 2400 mm
500m por tambor
H: 3500 mm L: 3500 mm
W: 2400 mm
Wight: 1100 kg
Equipos avanzados de fabricación
Equipos de prueba avanzados
La compañía presentó el equipo de prueba y producción de alambres y cables de nivel avanzado del mundo, como el analizador de espectro DV-6E, el probador de impurezas en micro poros en línea, etc.
Advanced Testing Equipment Guarantee Producción de alta calidad
1. Cable de alimentación de alta tensión 2.Hv Xlpe Cable 3. Cable corrugado de aluminio 4. Cable de acero blindado 5. Cinta de acero blindada
PRODUCTOS POR GRUPO : Cable de alimentación de alto voltaje