Especificación

ITEM DESCRIPTION UNIT REQUIRED SCHEDULE  A OFFERED SCHEDULE  B
38 800mm² 76/132kV 1C Cu XLPE CSA -----
1 Manufacturer Specify Beijing Huayuan Gaoke cable Co.,Ltd.
2 Country of Origin Specify CHINA
3 Rated voltage kV 145 76/132(145)
4 nominal diameter of conductor mm2 800 800
5 nominal thickness of conductor screen mm Specify 1.5(wrapping & extruding)
6 nominal thickness of core screen mm Specify 1.0 
7 nominal overall diameter of cable mm Specify 107.0 
8 mass of cable kg/m Specify 13890(approx.)
9 d.c. resistance of conductor at 20 °C Ω/km Specify 0.0221
10 a.c. resistance of conductor at 90 °C Ω/km Specify 0.0311
11 a.c. resistance of sheath with conductor at 90 °C Ω/km Specify 0.0724
12 reactance per phase Ω/km Specify 0.199
13 capacitance per phase nF/km Specify 189
14 zero sequence resistance and reactance Ω/km Specify 0.0311+j0.151(flat formation)
15 zero sequence capacitance nF/km Specify 189(flat formation)
16 rated continuous current A Specify

1040(in ground ,temperture 25℃,phase spacing 250mm,depth 1.2m 

,soil thermal resisitivity 1.0k.w/m ,1circuits)

17 rated symmetrical fault withstand current kA.s Specify 115(kA/1s conductor)
18 rated earth fault withstand current kA.s Specify 55(kA/1s Al sheath)
19 conductor temperature at specified load °C 90 max 90 max
20

conductor temperature after symmetrical fault (1 s) assumin

g operation at specified load before fault

°C Specify 250(not exceed 5s)
21

sheath temperature after earth fault (1 s) assuming operatio

n at specified load before fault

°C Specify 200(not exceed 5s)
22 conductor losses at maximum conductor operating temperature kW/km Specify 33.64(I=1040)
23

type test reports for the cables offered or for simila

r cables previously tested

Required
24 dimensioned drawing of the cable cross section Specify refer to the "structural drawing"
25 minimum installation bending radius m Specify 2.1
26 emergency current rating (IEC 60853-2) Specify 1206(I=1040,at 105℃,not more than 2h continuously)
27 cyclic current rating in accordance with IEC 60853-2 Specify

1040(in ground ,temperture 25℃,phase spacing 250mm,depth 1.2m 

,soil thermal resisitivity 1.0k.w/m ,1circuits)

Estructura del conductor

132(145)kV 1×800mm2


CU / XLPE / CAS / LLDPE 76/132 (145) kV 1 × 800 mm2

Structure

Nominal thickness mm

Nominal diameter mm

1 Water blocking stranded compacted circular copper conductor

\

34.0± 0.3

2  Semi-conductive tape

0.14

34.6

3  Conductor screen(wrapping & extruding)

1.5

37.0

4  XLPE insulation

18.0

73.0±1.5

5  Insulation screen

1.0

75.0

6  Semi-conductive tape

1.2

81.0

7  Corrugated  aluminum  sheath

2.0

96.5

8  Anticorrosive coating (bitumen)

0.25

97.0

9  LLDPE outer sheath

5.0

107.0

10 Semi-conductive layer(coatings)

 

107.0±3.0

La estructura de aluminio extruido no podría satisfacer la necesidad de resistencia al agua longitudinal


Nuestra compañía

Factory-1

Taller

undefinedundefined

Paquete

undefined

Entrega y pago

undefined

undefined

Honor

undefined



1.Three Core Copper Conductor 2.Five Core Copper Conductor 3.132kv Cable 4.High Voltage Cable de alimentación 5.Hv Xlpe Cable 6.Underground Cable

PRODUCTOS POR GRUPO : Cable de alimentación de alto voltaje

Contactar proveedor
  • *Asunto:
  • *Mensajes:
    Su mensaje debe ser de entre 20 a 8,000 caracteres.
Contactar Proveedor?Proveed
Crazy Zhang Mr. Crazy Zhang
¿Qué puedo hacer por ti?
Contactar Proveedor