http://es.bjhygkcable.com
Home > Lista de Productos > Cable de alimentación de voltaje medio > Aislamiento de XLPE del conductor de cobre 12KV con cable y línea de alimentación externos de la envoltura del PVC

Aislamiento de XLPE del conductor de cobre 12KV con cable y línea de alimentación externos de la envoltura del PVC

    Tipo de Pago: L/C,T/T,D/P
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Cantidad de pedido mínima: 500 Meter
Información básica

ModeloYJV

MarcaHUAYUAN YONGTONG

Información adicional

PaqueteTambores

productividad100KM/M

transporteOcean,Land,Air

Lugar de origenBEIJING, CHINA

Apoyo sobre100KM/M

Certificados CE,ISO,CCC

HS-Code8544601200

HafenTianjin Port,Shanghai Port,Beijing

Tipo de PagoL/C,T/T,D/P

IncotermFOB,CFR,CIF,FCA,CPT

Descripción

HOJA DE DATOS TECHNICLA PARA CABLE DE ALIMENTACIÓN 12kV 3C 50 SQmm

NO. ITEM  UNIT DATA
1 Name of Manufacturer: Beijing Huayuan Gaoke
Cable Co.,Ltd. 
1.2 Country of Manufacturer:  China 
2 Which type of manufacturing process viz. Continuous Catanery Vulcanisation (CCV) or vertical Catanery Vulcanisation system (VCV) or horizontal MDCV will be used to ensure circularity and concentricity of the extruded layers around the conductor. CCV
3 Type of Cable: Cu/XLPE /PVC
4 Rated nominal voltage kV 6.6/12
5 Rated Maximum voltage kV 12
6 Nominal cross-sectional area of Conductor Sq.mm 50
7 Conductor
7.1 Material Copper
7.2  Shape & formation Round
7.3  Diameter of conductor  mm 8.3
7.4 Dia.Of Single Wire/Number of strands mm 2.98/7
8 Conductor Screen 
8.1 Material semi conductive material
8.2 Thickness of semi-conductor  screen mm 0.6
8.3 Diameter of Semi-conductor(Approx.) mm 9.5
9 Insulation
9.1 Material XLPE
9.2 Insulation Thickness(Min.Avg.) mm 3.4
9.3 Diameter of Insulation(Approx.) mm 16.3
10 Insulation Screen
10.1 Material Semi-conductive material
10.2 Insulation Screen Thickness(Approx.) mm 0.8
10.3 Diameter of Sime-Insulation(Approx.) mm 17.9
11  Metallic Screen:
11.1 Material Plain Annealed Copper Tape
11.2 Thickness of the copper tape screen mm 0.1
11.3  Diameter of the cable across the metallic screen(Approx.) mm 18.2
12 Filler
12.1 Material Non-hygroscopic Filler
12.2 Diameter of Laid-Up Core 39.3
13 Bedding tape
13.1  Material Nonwoven tape
13.2 Approximate thickness  mm 0.2
13.3 Diameter over of bedding (Approx.) mm 40.5
16 Outer Sheath
16.1 Material PVC
16.2 Outer Sheath Thickness(Nominal) 2.4
16.3 Over Diameter(Approx.) 45.3
17 Conductor Weight kg/km 1256
17.1 Total Cable Weight (Approx.) kg/km 2791
18 Minimum Bending Radius
18.1 During Installation mm 1800
18.2 Installed mm 1600
19 Maximum Pulling Tension
19.1 Of Conductor kN 10.5
20  Continuous current rating under the specified installation and operating conditions.    Conductor temperature 90° C    . Ground    temperature 25° C    and    depth    of laying 1000 mm
20.2 In Ground Amp 162
21 Maximum value of electric stresses at the conductor screen (Calculation to be shown separately)  kV/mm  2.57
21.1 Maximum value of dielectric stress at the insulation  kV/mm  1.5
22 Short circuit capacity of conductor for 1/2/3    second assuming    conductor temperature of 90 ° C prior to short    circuit and 250 ° C during short circuit
22.1 1.0 Secs kA 7.5
22.2 2.0 Secs kA 5.4
22.3 3.0 Secs kA 4.3
23 Short circuit capacity of metallic screen    for    1/2/3 second     at     screen temperature of 80 ° C prior to short circuit    and 200 ° C during short circuit
23.1 1.0 Secs kA 2.8
23.2 2.0 Secs kA 2.1
23.3 3.0 Secs kA 1.6
24 Screen voltage under maximum operating conditions assuming all circuits connected kV per km 0.05
25 TEST
25.1 Maximum D.C. resistance of conductor  per km. at 20 degree C.  Ohm 0.387
25.2 Maximum A.C. resistance of conductor per km. at 90 degree C.  Ohm 0.495
25.3  Maximum electrostatic capacitance per km. of cable. μF 0.238
25.4 Partial discharge at 1.50 Uo pc 10
25.5 A.C.  Enduring Test voltage 2.5U0/ hours  kV/mim 16.5/5
25.6 D.C.Out sheath  Enduring Test voltage  kV/mim 5kV/1min
25.7 Impulse test voltage kV 65
26 Approximate drum dimension (dia & width) mm/mm 2200*1400
27 Maximum length of cable in a drum (Metres) m 900
28 Minimum length of cable in a drum  (Metres) m 800
39 Approximate gross weight of cable in a drum  TON 2.6
30 Expected Cable life. Year 30

Dibujo de configuración

 Cu/XLPE/PVC 12 kV 3×50mm2



Cu / XLPE / PVC 12 kV 3 × 50 mm 2

Construction

Thickness(mm)

Diameter(mm)

1 --- Copper Conductor

 

 8.3(+0.1,-0.1)

2 --- Conductor screen

0.6

 9.5

3 --- XLPE insulation

3.4

 16.3(+0.5,-0.5)

4 --- Insulation screen

0.8

 17.9

5 --- Copper tape screen

0.1

 18.2

6 --- PP filler

 

39.3

7 --- Non-woven fabrics tape

0.2

 40.5

8--- PVC outer sheath

2.4

45.3(+2.0,-2.0)


Equipos avanzados de fabricación

Product Equipment


Equipos de prueba avanzados

La compañía presentó el equipo de prueba y producción de alambres y cables de nivel avanzado del mundo, como el analizador de espectro DV-6E, el probador de impurezas en micro poros en línea, etc.

Advanced Testing Equipment Guarantee Producción de alta calidad

Test Equipment

Paquetes

Packages

Nuestro honor

Obtuvimos confianza y elogio de todos los clientes por su excelente calidad y buena reputación. Para proporcionar productos y servicios de primera clase para la sociedad es la búsqueda de personal de nuestra empresa para siempre. El departamento de servicio posventa ofrece una serie de servicios de venta previa y posterior a la venta, que resuelven las preocupaciones de los clientes y brindan un servicio completo y rápido para los clientes. La satisfacción de los clientes es la mejor rentabilidad para el personal de nuestra empresa.

Certificates


Cable 1.11kv Cable de alimentación de voltaje 2.Middle Conductor de cobre de la base 3.Five Cable de la sola base 4.Pvc Conductor de cobre de la base 5.Three

PRODUCTOS POR GRUPO : Cable de alimentación de voltaje medio

Contactar proveedor
  • *Asunto:
  • *Mensajes:
    Su mensaje debe ser de entre 20 a 8,000 caracteres.
Contactar Proveedor?Proveed
Crazy Zhang Mr. Crazy Zhang
¿Qué puedo hacer por ti?
Contactar Proveedor