Huayuan Gaoke Cable Co.,Ltd.
Cable aéreo para líneas de transmisión,ACAR Overhead Conductors Cable,Cables de conductores de aleación de aluminio
Tipo de Pago: | L/C,T/T,D/P,Paypal,Money Gram,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT,CIP |
Cantidad de pedido mínima: | 1000 Meter |
Modelo: ACAR
Marca: HUAYUAN YONGTONG
Paquete: Tambor
productividad: 1000km/M
transporte: Ocean,Land,Air
Lugar de origen: Beijing, China
Apoyo sobre: 1000km/M
Certificados : CE,CCC,ISO
Hafen: Tianjin Port,Shanghai Port,Qingdao Port
Tipo de Pago: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
1) CSC-NPA-LT-NPAPA- HCTEM-0001
2) CSC-NPA-LT-NPACON- HCTEM-0001
3) CSC-NPA-LT-NPAPAR- HCTEM-0001
ITÉM |
FEATURES |
UNIT |
REQUESTED |
GUARANTEED |
1 |
MANUFACTURER |
|||
1.1 |
Name |
- |
indicate |
Beijing Huayuan |
1.2 |
Country |
- |
indicate |
CHINA |
2 |
COMPLETE CONDUCTOR FEATURES |
|||
2.1 |
Conductor type |
- |
ACAR |
ACAR |
2.2 |
Standards that fulfill |
- |
ASTM B-524 |
ASTM B-524 |
2.3 |
Nominal Cross section |
mm2 |
380 |
380 |
2.4 |
Nominal external diameter |
mm |
25.31 |
25.31 |
2.5 |
Nominal unit weight |
kg/km |
1047 |
1049 |
2.6 |
Minimum breaking strength |
kg |
7056 |
7056 |
2.7 |
Number of wires |
each |
30/7 |
30/7 |
2.8 |
Elasticity module |
|||
· Initial |
kg/mm2 |
indicate |
5700 |
|
· Final |
kg/mm2 |
indicate |
5700 |
|
2.9 |
Linear expansion Coefficient |
1/°C |
23 x 10-6 |
23 x 10-6 |
2.1 |
A.C. Electrical resistance , 50 hz ,at 25 °C |
Ω/km |
indicate |
≤0.09795 |
2.11 |
Coefficient of variation of electrical resistance with temperature. |
1/°C |
indicate |
0.00403 |
2.12 |
Reactance at 1 foot and 50 Hz |
|
|
|
· Inductive |
Ω/km |
indicate |
0.233 |
|
· Capacitive |
Ω/km |
indicate |
/ |
|
2.13 |
Geometric Mean Radius |
mm |
indicate |
/ |
3 |
ALUMINUM ALLOY WIRES |
|||
3.1 |
Standards that fulfill |
- |
ASTM B-398 |
ASTM B-398 |
3.2 |
Nominal diameter |
mm |
3.62 |
3.62 |
3.3 |
Minimum Conductivity at 20°C, 50 Hz |
% IACS |
indicate |
53.5 |
3.4 |
Minimum average breaking strength |
|||
· before wiring |
MPa |
indicate |
315 |
|
· after wiring |
MPa |
indicate |
302 |
|
3.5 |
Minimum average elongation at 254 mm |
|||
· before wiring |
% |
indicate |
3 |
|
· after wiring |
% |
indicate |
2 |
|
3.6 |
Type of welding and welding wire treatment |
- |
indicate |
cold welding |
3.7 |
Minimum tensile strength on welded wire |
MPa |
indicate |
302 |
3.8 |
Elasticity module |
MPa |
indicate |
56000 |
3.9 |
Linear expansion Coefficient |
1/°C |
23 x 10-6 |
23 x 10-6 |
3.1 |
Chemical composition |
|||
· Aluminum, mínimum |
% Peso |
indicate |
97.28 |
|
· Copper, máximum |
% Peso |
indicate |
0.1 |
|
· iron , máximum |
% Peso |
indicate |
0.5 |
|
· Silicon , range |
% Peso |
indicate |
0.50-0.9 |
|
· Manganese, máximum |
% Peso |
indicate |
0.03 |
|
· Magnesium, máximum range |
% Peso |
indicate |
0.6-0.9 |
|
· Zinc, máximum |
% Peso |
indicate |
0.10 |
|
· Chromo, máximum |
% Peso |
indicate |
0.03 |
|
· Boron, máximum |
% Peso |
indicate |
0.06 |
|
· Others elements, máximum |
% Peso |
indicate |
0.10 |
|
4 |
REELS |
|||
4.1 |
Nominal length of the continuous cable strip |
m |
2000 |
2000 |
4.2 |
Reel gross weight , including OPGW cable and lathing |
kg |
indicate |
2298(including ACAR ) |
4.3 |
External diameter over lathing |
cm |
indicate |
180 |
4.4 |
Flange diameter |
cm |
indicate |
180 |
4.5 |
Drum diameter |
cm |
indicate |
180 |
4.6 |
Inside width , between flanges |
cm |
indicate |
940 |
4.7 |
External width |
cm |
indicate |
1100 |
4.8 |
Hole diameter for axis |
cm |
indicate |
160 |
4.9 |
Number of bolts of flanges |
- |
indicate |
8 |
4.1 |
Material from which the reel is made |
- |
indicate |
TBEA |
5 |
QUANTITIES |
|||
5.1 |
ACAR CONDUCTOR |
km |
1830 |
1830 |
6 |
TESTS |
|||
6.1 |
Test list |
- |
indicate |
YES |
6.2 |
Test Protocols |
- |
indicate |
YES |
6.3 |
Period of tests in factory |
- |
indicate |
YES |
7 |
DELIVERY TIME |
|||
7.1 |
Delivery date certified information |
- |
indicate |
|
7.2 |
Delivery term |
- |
indicate |
|
7.3 |
Certified information, catalogs, plans, etc. |
- |
indicate |
|
7.4 |
Gantt chart |
- |
indicate |
|
Estructura del conductor para ACAR 750 MCM
Construction |
Nominal NO./Diameter(mm) |
Nominal Diameter(mm) |
1--- Aluminum Alloy Wire |
7 / 3.62 |
10.86 |
2--- Aluminum Wire |
30 / 3.62 |
25.34 |
Requisitos de prueba para Overhead Conductor
Los siguientes elementos de prueba se llevarán a cabo de conformidad con las normas pertinentes de ASTM.
No. |
Test item |
Tests(The user has no special requirements) |
|
1 |
Tensile Strength and Elongation Requirements (test frequency 10%)Before strands |
2 |
Resistivity test(test frequency 10%) |
3 |
Structural inspection(test frequency 10%) |
Paquete
Pago y entrega
Honor
PRODUCTOS POR GRUPO : Cable aéreo