Huayuan Gaoke Cable Co.,Ltd.
Copper Conductor XLPE Insulation PP Filler,Cable NA2XS2Y N2XS2Y,Cubierta exterior de PVC de la pantalla de la cinta de cobre para el cable
Tipo de Pago: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Cantidad de pedido mínima: | 500 Meter |
Modelo: NA2XS2Y
Marca: HUAYUAN YONGTONG
Paquete: Tambores
productividad: 100KM/M
transporte: Ocean,Land,Air
Lugar de origen: BEIJING, CHINA
Apoyo sobre: 100KM/M
Certificados : CE ISO CCC
HS-Code: 8544601300
Hafen: Shanghai Port,Tianjin Port,Qingdao Port
Tipo de Pago: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
FICHA TÉCNICA TECHNICLA PARA CABLE DE ALIMENTACIÓN DE 36 kV 3C 70 SQmm
NO. | ITEM | UNIT | DATA |
1 | Name of Manufacturer: | Beijing Huayuan Gaoke | |
Cable Co.,Ltd. | |||
1.2 | Country of Manufacturer: | China | |
2 | Which type of manufacturing process viz. Continuous Catanery Vulcanisation (CCV) or vertical Catanery Vulcanisation system (VCV) or horizontal MDCV will be used to ensure circularity and concentricity of the extruded layers around the conductor. | CCV | |
3 | Type of Cable: | Cu/XLPE/AWA/PVC | |
4 | Rated nominal voltage | kV | 20/36 |
5 | Rated Maximum voltage | kV | 36 |
6 | Nominal cross-sectional area of Conductor | Sq.mm | 70 |
7 | Conductor | ||
7.1 | Material | Copper | |
7.2 | Shape & formation | Round | |
7.3 | Diameter of conductor | mm | 10.0 |
7.4 | Dia.Of Single Wire/Number of strands | mm | 2.17/19 |
8 | Conductor Screen | ||
8.1 | Material | semi conductive material | |
8.2 | Thickness of semi-conductor screen | mm | 0.8 |
8.3 | Diameter of Semi-conductor(Approx.) | mm | 11.6 |
9 | Insulation | ||
9.1 | Material | XLPE | |
9.2 | Insulation Thickness(Min.Avg.) | mm | 8.0 |
9.3 | Diameter of Insulation(Approx.) | mm | 27.6 |
10 | Insulation Screen | ||
10.1 | Material | Semi-conductive material | |
10.2 | Insulation Screen Thickness(Approx.) | mm | 1.0 |
10.3 | Diameter of Sime-Insulation(Approx.) | mm | 29.2 |
11 | Metallic Screen: | ||
11.1 | Material | Plain Annealed Copper Tape | |
11.2 | Thickness of the copper tape screen | mm | 0.10 |
11.3 | Diameter of the cable across the metallic screen(Approx.) | mm | 29.5 |
12 | Filler | ||
12.1 | Material | Non-hygroscopic Filler | |
12.2 | Diameter of Laid-Up Core | 63.7 | |
13 | Bedding tape | ||
13.1 | Material | Nonwoven tape | |
13.2 | Approximate thickness | mm | 0.2 |
13.3 | Diameter over of bedding (Approx.) | mm | 68.4 |
14 | Inner Sheath | ||
14.1 | Material | PVC | |
14.2 | Inner Sheath Thickness(Nominal) | 1.9 | |
14.3 | Diameter over the Inner sheath(Approx.) | 68.7 | |
15 | Armouring | ||
15.1 | Material | Steel tape | |
15.2 | Approximate diameter or thickness | mm/ | 0.5 |
15.3 | Diameter of armouring (Approx.) | mm | 70.7 |
16 | Outer Sheath | ||
16.1 | Material | PVC | |
16.2 | Outer Sheath Thickness(Nominal) | 3.4 | |
16.3 | Over Diameter(Approx.) | 77.5 | |
17 | Conductor Weight | kg/km | 1804 |
17.1 | Total Cable Weight (Approx.) | kg/km | 7650 |
18 | Minimum Bending Radius | ||
18.1 | During Installation | mm | 1500 |
18.2 | Installed | mm | 1200 |
19 | Maximum Pulling Tension | ||
19.1 | Of Conductor | kN | 14.7 |
20 | Continuous current rating under the specified installation and operating conditions. Conductor temperature 90° C . Ground temperature 25° C and depth of laying 1000 mm | ||
20.2 | In Ground | Amp | 245 |
21 | Maximum value of electric stresses at the conductor screen (Calculation to be shown separately) | kV/mm | 3.98 |
21.1 | Maximum value of dielectric stress at the insulation | kV/mm | 1.67 |
22 | Short circuit capacity of conductor for 1/2/3 second assuming conductor temperature of 90 ° C prior to short circuit and 250 ° C during short circuit | ||
22.1 | 1.0 Secs | kA | 10.0 |
22.2 | 2.0 Secs | kA | 7.1 |
22.3 | 3.0 Secs | kA | 5.8 |
23 | Short circuit capacity of metallic screen for 1/2/3 second at screen temperature of 80 ° C prior to short circuit and 200 ° C during short circuit | ||
23.1 | 1.0 Secs | kA | 4.5 |
23.2 | 2.0 Secs | kA | 3.2 |
23.3 | 3.0 Secs | kA | 2.8 |
24 | Screen voltage under maximum operating conditions assuming all circuits connected | kV per km | 0.05 |
25 | TEST | ||
25.1 | Maximum D.C. resistance of conductor per km. at 20 degree C. | Ohm | 0.268 |
25.2 | Maximum A.C. resistance of conductor per km. at 90 degree C. | Ohm | 0.34 |
25.3 | Maximum electrostatic capacitance per km. of cable. | μF | 0.148 |
25.4 | Partial discharge at 1.50 Uo | pc | ≤ 10 |
25.5 | A.C. Enduring Test voltage 2.5U0/ hours | kV/mim | 70/5 |
25.6 | D.C.Out sheath Enduring Test voltage | kV/mim | 5kV/1min |
25.7 | Impulse test voltage | kV | 170 |
26 | Approximate drum dimension (dia & width) | mm/mm | 2800*1700 |
27 | Maximum length of cable in a drum (Metres) | m | 600 |
28 | Minimum length of cable in a drum (Metres) | m | 500 |
39 | Approximate gross weight of cable in a drum | TON | 4.2 |
30 | Expected Cable life. | Year | 30 |
Cu / XLPE / STA / PVC 20/36 kV 3 × 70mm 2
Construction |
Thickness(mm) |
Diameter(mm) |
1 --- Copper Conductor |
|
10.0(+0.1,-0.1) |
2 --- Conductor screen |
0.8 |
11.6 |
3 --- XLPE insulation |
8.0 |
27.6(+0.8,-0.5) |
4 --- Insulation screen |
1.0 |
29.2 |
5 --- Copper tape screen |
0.1 |
29.5 |
6 --- PP filler |
|
63.7 |
7 --- Non-woven fabrics tape |
0.2 |
64.9 |
8 --- PVC inner sheath |
1.9 |
68.7(+1.5,-1.5) |
9 --- Steel tape armour |
0.5 |
70.7 |
10--- PVC outer sheath |
3.4 |
77.5(+2.5,-2.0) |
Equipos avanzados de fabricación
Equipos de prueba avanzados
La compañía presentó el equipo de prueba y producción de alambres y cables de nivel avanzado del mundo, como el analizador de espectro DV-6E, el probador de impurezas en micro poros en línea, etc.
Advanced Testing Equipment Guarantee Producción de alta calidad
1. Cable de alimentación de alta tensión 2.Hv Cable de Xlpe 3.33kv Cable 4. Alta calidad 3 Core Power Cable 5.Fice Core Copper Conductor 6.Three Core Copper Conductor
PRODUCTOS POR GRUPO : Cable de alimentación de voltaje medio